Where nn is the amount in one-tenth of a dB to
decrease the gain. nn can be single digit ( n ),
double digit ( nn ), triple digit ( nnn ).
Command String:
< SET x AUDIO_GAIN_HI_RES DEC nn >
Where yyyy takes on the ASCII values of 0000 to
1400.
MXA910 Response:
< REP x AUDIO_GAIN_HI_RES yyyy >
Get Channel Audio Mute
Where x is ASCII channel number: 0 through 9.
Channel Audio Mute is pre-meter
Command String:
< GET x AUDIO_MUTE >
The MXA910 will respond with one of these strings.
MXA910 Response:
< REP x AUDIO_MUTE ON >
< REP x AUDIO_MUTE OFF >
Mute Channel Audio
Command String:
< SET x AUDIO_MUTE ON >
MXA910 Response:
< REP x AUDIO_MUTE ON >
Unmute Channel Audio
Command String:
< SET x AUDIO_MUTE OFF >
MXA910 Response:
< REP x AUDIO_MUTE OFF >
Toggle Channel Audio Mute
Command String:
< SET x AUDIO_MUTE TOGGLE >
The MXA910 will respond with one of these strings.
MXA910 Response:
< REP x AUDIO_MUTE ON >
< REP x AUDIO_MUTE OFF >
Get Device Audio Mute
Device Audio Mute is post-meter.
Command String:
< GET DEVICE_AUDIO_MUTE >
The MXA910 will respond with one of these strings.
MXA910 Response:
< REP DEVICE_AUDIO_MUTE ON >
< REP DEVICE_AUDIO_MUTE OFF >
Mute Device Audio
Command String:
< SET DEVICE_AUDIO_MUTE ON >
MXA910 Response:
< REP DEVICE_AUDIO_MUTE ON >
Unmute Device Audio
Command String:
< SET DEVICE_AUDIO_MUTE OFF >
MXA910 Response:
< REP DEVICE_AUDIO_MUTE OFF >
Toggle Device Audio Mute
Command String:
< SET DEVICE_AUDIO_MUTE TOGGLE >
Shure IncorporatedMXA910 Ceiling Array Microphone