The MXA910 will respond with one of these strings.
MXA910 Response:
< REP DEVICE_AUDIO_MUTE ON >
< REP DEVICE_AUDIO_MUTE OFF >
Get Output Clip Status
Where x is ASCII channel number: 0 through 9. It
is not necessary to continually send this command.
The MXA910 will send a REPORT message
whenever the status changes.
Command String:
< GET x AUDIO_OUT_CLIP_INDICATOR >
The MXA910 will respond with one of these strings.
MXA910 Response:
< REP x AUDIO_OUT_CLIP_INDICATOR ON >
< REP x AUDIO_OUT_CLIP_INDICATOR OFF >
Flash Lights on Microphone
Send one of these commands to the MXA910.The
flash automatically turns off after 30 seconds.
Command String:
< SET FLASH ON >
< SET FLASH OFF >
The MXA910 will respond with one of these strings.
MXA910 Response:
< REP FLASH ON >
< REP FLASH OFF >
Get Metering Rate
Command String:
< GET METER_RATE >
Where aaa, bbb, etc is the value of the audio level
received and is 000-060.
aaa = output 1
bbb = output 2
ccc = output 3
ddd = output 4
eee = output 5
fff = output 6
ggg = output 7
hhh = output 8
iii = output 9
MXA910 Response:
< REP METER_RATE sssss >
< SAMPLE aaa bbb ccc ddd eee fff ggg hhh iii >
Turn Metering On
Where sssss is the metering speed in milliseconds.
Setting sssss=0 turns metering off. Minimum setting
is 100 milliseconds. Metering is off by default.
Command String:
< SET METER_RATE sssss >
Where aaa, bbb, etc is the value of the audio level
received and is 000-060.
aaa = output 1
bbb = output 2
ccc = output 3
ddd = output 4
eee = output 5
fff = output 6
ggg = output 7
hhh = output 8
iii = output 9
MXA910 Response:
< REP METER_RATE sssss >
< SAMPLE aaa bbb ccc ddd eee fff ggg hhh iii >
Stop Metering
A value of 00000 is also acceptable.
Command String:
< SET METER_RATE 0 >
Shure IncorporatedMXA910 Ceiling Array Microphone
2017/10/1844/57