MXA910 Response:
< REP LED_STATE_MUTED nnn >
Get LED Unmute Flashing
Command String:
< GET LED_STATE_UNMUTED >
Where nnn can be ON, OFF, or FLASHING
MXA910 Response:
< REP LED_STATE_UNMUTED nnn >
Set LED Unmute Flashing
Where nnn can be ON, OFF, or FLASHING
Command String:
< SET LED_STATE_UNMUTED nnn >
MXA910 Response:
< REP LED_STATE_UNMUTED nnn >
Get X-Axis Beam (Lobe) Steering
Where the X-Axis is parallel with the Shure logo.
Command String:
< GET x BEAM_X >
Where nnnn is 0000-3048 in centimeters.The value
1524 is the centerline of the MXA910.
MXA910 Response:
< REP x BEAM_X nnnn >
Set X-Axis Beam (Lobe) Steering
Where nnnn is 0000-3048 in centimeters.The value
1524 is the centerline of the MXA910.
Command String:
< SET x BEAM_X nnnn >
MXA910 Response:
< REP x BEAM_X nnnn >
Get Y-Axis Beam (Lobe) Steering
Where the Y-Axis is perpendicular to the X-Axis.
Command String:
< GET x BEAM_Y >
Where nnnn is 0000-3048 in centimeters.The value
1524 is the centerline of the MXA910.
MXA910 Response:
< REP x BEAM_Y nnnn >
Set Y-Axis Beam (Lobe) Steering
Where nnnn is 0000-3048 in centimeters.The value
1524 is the centerline of the MXA910.
Command String:
< SET x BEAM_Y nnnn >
MXA910 Response:
< REP x BEAM_Y nnnn >
Get Beam (Lobe) Height
Where height is the distance down from the
MXA910.
Command String:
< GET x BEAM_Z >
Where nnn is 000-914 in centimeters.
MXA910 Response:
< REP x BEAM_Z nnn >
Set Beam (Lobe) Height
Where nnn is 000-914 in centimeters.
Command String:
< SET x BEAM_Z nnn >
MXA910 Response:
< REP x BEAM_Z nnn >
Get Beam (Lobe) Width
Command String:
< GET x BEAM_W >
Shure IncorporatedMXA910 Ceiling Array Microphone