EasyManua.ls Logo

SICK C4000 Standard

SICK C4000 Standard
124 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 8 Operating Instructions
C4000 Standard/Advanced
66 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 8009861/WA65/2012-06-12
Subject to change without notice
Configuration
8 Configuration
8.1 Default delivery status
As delivered the C4000 is configured ready for protective operation. The C4000 Standard
w
ithout extension connection is also available as an option with the pre-configurations C,
D, E, F and R. You can change the pre-configuration at any time with the aid of the CDS.
C4000 Standard with
pre@configuration …
Function that can be
configured
C4000
Standard
C4000
Advanced
C D E F R
Restart interlock External External External Internal External
External device
monitoring (EDM)
Deacti-
vated
Deacti-
vated
Activated Deactivated
Beam coding Non-coded Non-coded Non-coded
Blanking None None None
Guaranteed scanning
range
0-2.5 m or 0-6 m 
2-8 m or 5-19 m 
Function that can be
configured
C4000 Standard Guest C4000 Advanced Guest
Beam coding Non-coded Non-coded
Blanking None None
Guaranteed scanning
range
0-2.5 m 0-6 m
0-2.5 m or 0-6 m 
2-8 m or 5-19 m
8.2 Preparing the configuration
How to prepare the configuration:
Make sure that the safety light curtain has been correctly mounted and that the elec-
trical connections are correct and in place.
Plan all required settings (operating mode, beam coding, resolution, cascading etc.)
To configure the safety light curtain, you need:
CDS (Configuration & Diagnostic Software) on CDCROM
user manual for CDS on CDCROM
PC/Notebook with Windows NT/2000/XP/Vista and a serial interface (RSC232).
PC/Notebook not included
connecting cable for connecting PC and C4000 (SICK part number 6021195)
To configure the device, please read the user manual for the CDS (Configuration &
Diagnostic Software) and use the online help function of the programme.
Tab.
22
:
Default delivery
status of the C4000
Tab.
23
:
Default delivery
status of the C4000 Guest

Table of Contents