Chapter 11 Operating Instructions
C4000 Standard/Advanced
90 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 8009861/WA65/2012-06-12
Subject to change without notice
Technical specifications
11.5.8 Swivel mount bracket for C4000 Guest
Fig.
51
:
Swivel mount bracket
for C4000 Guest
9
32
44.4
29
60.4
32
SW13
60.4
44.4
13
15.3
9
29
13
6
6

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK C4000 Standard and is the answer not in the manual?

SICK C4000 Standard Specifications

General IconGeneral
TypeSafety Light Curtain
Number of BeamsVaries with protective field height and resolution
Safety Integrity LevelSIL3
Performance LevelPL e
Enclosure RatingIP65, IP67
Type IECType 4
CategoryCategory 4
Protective Field Height300 mm to 1800 mm
Supply Voltage24 V DC
ConnectionM12 connector
OutputsPNP
Resolution14 mm, 30 mm
Operating Temperature-25 °C ... +55 °C