Operating Instructions Chapter 11
C4000 Standard/Advanced
8009861/WA65/2012-06-12 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 85
Subject to change without notice
Technical specifications
11.5.2 C4000 Standard with angled system connection and without extension
connection
Protective field
height S [mm]
Dimension
L1 [mm]
Dimension
L2 [mm]
Dimension
A [mm]
300 381 397 224
450 532 548 374
600 682 698 524
900 984 1000 824
1050 1134 1150 974
Other systems on request.
Fig.
45
:
Dimensional drawing
C4000 Standard, sender with
angled system connection
and without extension
connection.
Receiver, mirror image
Tab.
37
:
Dimensions
dependent on the protective
field height, C4000 Standard
with angled system
connection and without
extension connection
48
22.4
74
A
Sliding nut groove for
side mounting
14
6
10.5
2.2
1
3.5
10
DIN
43
651 plug (M26
×
11
+
FE)
40
20
L1
L2
56.3
S
6.3
92
Cable sockets M26
×
11
+
FE
with
crimp contacts
Ca. 95
(connector range)
67
Ca. 135
(connector range)
65

Table of Contents

Related product manuals