7.13.3 Connecting preconfigured devices in an existing cascade
If you use a device that may already have been configured to extend a cascade or to
r
eplace a (defective) device in a cascade, reset the device to the factory settings first.
Further topics
"R
eset to factory settings", page 86
"Connecting a new device in an existing cascade", page 99
"Configuring beam coding", page 88
7.14 Status indication on both sides
The OSSD status and the status of the protective field are indicated via LEDs on the
sender and r
eceiver when the following applies:
The sender and receiver are connected to one another in the control cabinet
The sender and receiver are connected to one another via a T-connector
The status information is transferred from the receiver to the sender automatically. A
configuration process is not required.
Further topics
"C
onnection of sender and receiver", page 51
7 C
ONFIGURATION
100
O P E R A T I N G I N S T R U C T I O N S | deTec4 Ex II 3GD 8023872/18YZ/2021-01-14 | SICK
Subject to change without notice