11 Troubleshooting
11.1 Overview
Information on the status as well as diagnostics and troubleshooting of the safety light
c
urtain can be displayed as follows:
•
Diagnostics LEDs
Status and fault information, as well as diagnostics data, are displayed directly on
the sender and receiver by means of the diagnostics LEDs.
•
IO
-Link
Status and error information as well as diagnostics data can be read by means of
an IO
-link interface.
•
NF
C
Status and fault information, as well as diagnostics data, can be read out to an
NF
C-capable device by means of an integrated NFC interface.
Complementary information
You can find additional information on IO-Link in the IODD and the SDD for SOPAS ET.
You can find additional information on NFC in the SICK Safety Assistant app.
Further topics
•
"Dia
gnostic LEDs", page 115
11.2 Safety
DANGER
H
azard due to lack of effectiveness of the protective device
Persons and parts of the body to be protected may not be recognized in case of
non-observance.
b
Immediately shut the machine down if the behavior of the machine cannot be
clearly identified.
b
Immediately put the machine out of operation if you cannot clearly identify or
allocate the fault and if you cannot safely remedy the fault.
b
Secure the machine so that it cannot switch on unintentionally.
DANGER
H
azard due to unexpected starting of the machine
b
When any work is taking place, use the protective device to secure the machine or
to ensure that the machine is not switched on unintentionally.
DANGER
H
azard due to lack of effectiveness of the protective device
Persons and parts of the body to be protected may not be recognized in case of
non-observance.
b
Do not do repair work on device components.
b
Do not make changes to or manipulate device components.
b
Apart from the procedures described in this document, the device components
must not be opened.