Complementary information
Ext
ernal device monitoring is deactivated on delivery.
Further topics
•
"Ext
ernal device monitoring (EDM)", page 49
•
"Factory settings", page 86
7.12 Configuring application diagnostic output
Overview
T
he application diagnostic outputs are configured automatically:
The following signals can be output over the application diagnostic output:
•
Weak signal
•
Reset required
•
Ignored object
•
Muting status
•
Override required
A signal can be output on both the system and extension connections.
Table 33: Output signals on the system connection and extension connection
Configured function Output signal on the
applic
ation diagnostic
output of the system
connection
Output signal on the application diagnostic
output of the extension connection
Not configured (fac‐
t
ory settings)
Weak signal
1)
Weak signal
1)
Reduced resolution Ignored object
2)
Weak signal
1)
Restart interlock with
reset pushbutton on
the system connection
Reset required Weak signal
1)
Restart interlock with
r
eset pushbutton on
the extension connec‐
tion
Weak signal
1)
or
ignored object
2)
Reset required
Muting on In1 and In2 Override required Muting condition or override required
Muting on In2 and In4 Muting status or over‐
ride required
Muting status or override required
Muting on In1 and In2
and r
estart interlock
with reset pushbutton
on the system connec‐
tion
Reset required or over‐
ride required
Muting status or reset required or override
required
Muting on In2 and In4
and restart interlock
with reset pushbutton
on the system connec‐
tion
Muting status or reset
required or override
required
Muting status or reset required or override
required
1)
A weak signal is only signaled if no other output signal is configured on the respective application
dia
gnostic output.
2)
An ignored object is only signaled if neither a restart interlock on the system connection nor muting are
configured.
CONFIGURATION 7
8023872/18YZ/2021-01-14 | SICK O P E R A T I N G I N S T R U C T I O N S | deTec4 Ex II 3GD
97