7.2 Factory settings
Table 26: Configurable functions when delivered
Function Configuration when delivered
Beam coding. Uncoded
Restart interlock Not configured
External device monitoring (EDM) Not configured
Cascading Single system
Smart presence detection Not configured
Reduced resolution Not configured
Muting Not configured
Partial blanking Not configured
Scanning range adjustment Automatic calibration of the protective field
w
idth
Complementary information
T
he device must be reset to the factory settings to change the configuration to the
following functions:
•
External device monitoring (EDM)
•
Restart interlock
•
Cascading
All other functions can be changed later on without having to reset the safety light
curtain to the factory settings.
Further topics
•
"R
eset to factory settings", page 86
7.2.1 Reset to factory settings
Overview
T
he sender and receiver are reset to factory settings independently of each other. The
procedure is the same for the sender and receiver.
The following functions must be reset to factory settings following a certain proce‐
dure:
•
External device monitoring (EDM)
•
Restart interlock
•
Cascading
The device must also be reset to the factory settings if the device has previously used
the functions of the SP2 system plug and is now to be operated with an SP1 system
plug.
All other functions will be reset to the factory settings by setting the DIP switches to Off.