OFF
uncoded
code 1
code 2
rev.conf.
ON
1
O N
2
Figure 50: SP1 system plug with 2 DIP
s
witches
OFF
uncoded
code 1
code 2
rev.conf.
ON
1 2 3 4
O F F
1 2 3 4
O F F
1 2 3 4
O F F
1
O N
2
A
B
C
D
Figure 51: SP2 system plug with 14 DIP
s
witches
Table 25: Overview of DIP switches
Row DIP switch Function
A
1)
1, 2, 3, 4 Muting, see "C
onfiguring muting", page 89
B
1)
1, 2 Scanning range adjustment, see "Configuring
the scanning range", page 91
3, 4 Reduced resolution, see "C
onfiguring reduced
resolution", page 92
C
1)
1 Smart presence detection, see "Configuring
smart presence detection", page 93
2, 3 Not Assigned
4 Parity, see "Chec
king the parity", page 94
D 1, 2
•
Be
am coding, see "Configuring beam cod‐
ing", page 88
•
Reset to factory settings, see "Reset to fac‐
tory settings", page 86
1)
Only applies to SP2 system plug.
Configuration information
b
Chec
k the parity using the SP2 system plug after setting the DIP switches. The
sum of the DIP switches of rows A, B and C set to On must be even. In case of an
uneven sum, change the setting of DIP switch 4 (row C).
b
Securely close the protective cover for the DIP switches, which is attached to the
SP2 system plug.
b
Then ensure the correct functioning of the device.
Further topics
•
"S
ystem plug", page 17
•
"Configuring the restart interlock", page 95
•
"Configuring external device monitoring (EDM)", page 96
CONFIGURATION 7
8023872/18YZ/2021-01-14 | SICK O P E R A T I N G I N S T R U C T I O N S | deTec4 Ex II 3GD
85
Subject to change without notice