DANGER
H
azard due to lack of effectiveness of the protective device
Persons and parts of the body to be protected may not be recognized in case of
non-observance.
b
Only mount deflector mirrors to solid walls or machine components. The position
of the deflector mirrors must not change after alignment.
b
Do not use deflector mirrors if contamination, beading water, condensation, or
frost on the deflector mirrors is to be expected.
b
Make sure that the deflector mirrors are intact and free of scratches, contamina‐
tion, beading water, condensation, frost, etc. at all times.
Further topics
"Mir
ror columns", page 146
15.5.2 Mounting
To mount the deflector mirrors, use the included swivel mount brackets.
15.5.3 Change in scanning range using deflector mirrors
Important information
NOTE
The use of deflector mirrors reduces the scanning range depending on the number of
deflector mirrors in the protective field.
Table 73: Scanning range with and without 1 or 2 deflector mirrors
Type Solution Scanning
ran
ge, typi‐
cal
Scanning range with
1 deflector mirror, typi‐
cal
Scanning range with
2 deflector mirrors, typi‐
cal
PNS75, PNS125 14 mm 20 m D1 + D2 ≤ 18 m D1 + D2 + D3 ≤ 16.2 m
PNS75, PNS125 30 mm 30 m D1 + D2 ≤ 27 m D1 + D2 + D3 ≤ 24.3 m
Example: Recommended distance when using deflector mirrors
T
his example assumes a 90° beam deflection per mirror, and a protective field height
of 900 mm.
When using a PNS75 deflector mirror, a distance of D
1
, D
2
, D
3
≤ 4 m between the
deflector mirror and the device, or between 2 mirrors is recommended.
When using a PNS125 deflector mirror, a distance of D
1
, D
2
, D
3
≤ 8 m between the
deflector mirror and the device, or between 2 mirrors is recommended.
D
1
D
2
s
r
D
1
D
2
s
r
D
3
Figure 68: Recommended distance when using deflector mirrors