Complementary information
O
verride is connected to the 8-pin system connection.
Detailed information on using the muting connector can be found in the assembly
instructions for the muting connector.
Further topics
"Cr
oss-circuit monitoring", page 44
"Electrical installation", page 78
"Accessories", page 139
4.4.11 Connection diagrams
5-pin, RLY3-OSSD2 safety relay
deTec4
1
2
4
3
5
2
)
3) PELV
r
System connection
+24 V DC
OSSD1
OSSD2
0 V
Com1
1
2
4
3
5
s
System connection
+24 V DC
In2
In1
0 V
C
om1
SI SI
H1 H2
+24 V DC
0 V DC
K1K2
E202115/00/2018-02-06
R1 Y1 Y2 24A2 14
S
1 I1 I2 23A1 13
RLY3-OSSD2
k2
k1
S1
k2
z
k1 k2
k1
z
x
y
x
1)
y
1) Output circuits: These contacts must be incorporated into the control such that the
dangerous state is brought to an end if the output circuit is open. For categories 4 and 3,
they must be incorporated on dual-channels (x, y paths). Type 2 devices are suitable for
use up to PL c. Single-channel incorporation into the control (z path) is only possible with
a single-channel control and taking the risk analysis into account.
2) To indicate the status on both sides, the Com1 connections from the sender and receiver
must be connected to each other in the control cabinet (optional).
3) SELV/PELV safety extra-low voltage.
T
ask
Connection of a deTec4 Ex II 3GD safety light curtain to a RLY3-OSSD2 safety
r
elay. Operating mode: With restart interlock and external device monitoring.
Mode of opera
tion
When the protective field is clear, the OSSD1 and OSSD2 outputs carry voltage.
T
he system can be switched on when K1 and K2 are in a fault-free de-energized
position. Lamp H2 flashes. The RLY3-OSSD2 is switched on by pressing S1 (push‐
button is pressed and released). The outputs (contacts 13-14 and 23-24) switch
4 P
ROJECT PLANNING
56
O P E R A T I N G I N S T R U C T I O N S | deTec4 Ex II 3GD 8023872/18YZ/2021-01-14 | SICK
Subject to change without notice