Using reversed direction of transmission
T
he direction of transmission of the system " can be changed during mounting by
switching the positions of the sender and receiver. With reversed direction of mounting,
the receiver " is not affected by the infrared light from the sender !.
"
!
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
rs
r
Figure 17: Trouble-free operation due to reversed direction of transmission of system
1
and
system
2
Further topics
"Connection of sender and receiver", page 51
"Combining beam coding and reversed direction of transmission", page 35
4.3.4.3 Combining beam coding and reversed direction of transmission
To prevent a mutual interference in the case of more than two neighboring systems,
be
am coding and reversed direction of transmission can be combined.
s r
Code 1
s r
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
r
r
r
r
r
s
r
r
r
r
r
s
rs
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
rs
Code 2
Code 2Code 1
Figure 18: Trouble-free operation of 4 neighboring systems due to beam coding and reversed
dir
ection of transmission
In the figure, the beam coding of the systems arranged next to each other is different.
The direction of transmission of the systems arranged on top of each other is reversed.
This prevents the systems from interfering with each other.
4.3.4.4 Using a sender with a small scanning range
Overview
In or
der to prevent mutual interference of systems, a sender with a small scanning
range can be used.
PROJECT PLANNING 4
8023872/18YZ/2021-01-14 | SICK O P E R A T I N G I N S T R U C T I O N S | deTec4 Ex II 3GD