OFF
uncoded
code 1
code 2
rev.conf.
ON
1 2 3 4
O F F
1 2 3 4
O F F
1 2 3 4
O F F
1
O N
2
A
B
C
D
1 2 3 4
O F F
Figure 57: DIP switch for smart presence detection on SP2 system plug
Table 32: DIP switch and smart presence detection
DIP switch 1 (row C) Function
Off Smart presence detection inactive (delivery
condit
ion)
On Smart presence detection active
Note on configuration
b
Chec
k the parity after setting the DIP switch, see "Checking the parity", page 94.
7.9 Checking the parity
The parity must be checked after setting the DIP switches. The parity specifies whether
t
he sum of the DIP switches set to On is even or uneven.
Parity is only calculated for the DIP switches of rows A, B and C. DIP switches 1 and 2 of
row D are not included.
The parity is set using DIP switch 4 (row C).
7 C
ONFIGURATION
94
O P E R A T I N G I N S T R U C T I O N S | deTec4 Ex II 3GD 8023872/18YZ/2021-01-14 | SICK
Subject to change without notice