Table 6: Use of system plugs in a cascade
SP1 system plug type code SP2 system plug type code
1000 1100 1300 2100 2300
Host Sender
1)
Receiver
F
unctions at the
host
Beam coding
Functions at the
host
Beam coding
Restart inter‐
lock
External device
monitoring
Application
diagnostic out‐
put
Functions at the
host
Beam coding
Reduced reso‐
lution
Dynamic pro‐
tective field
width
Smart pres‐
ence detection
Functions at the
host
Beam coding
Reduced reso‐
lution
Dynamic pro‐
tective field
width
Restart inter‐
lock
External device
monitoring
Application
diagnostic out‐
put
Smart pres‐
ence detection
First guest
(
for cascade
with 2 guest
devices)
Sender
Receiver
Last guest Sender
2)
Receiver
F
unctions at the
last guest
External device
monitoring
Restart inter‐
lock
Application
diagnostic out‐
put
IO-Link
System plug suitable.
System plug not suitable. An SP1 system plug must be used on the receiver of a guest system as well as on the sender of a host system
and gue
st system.
1)
At the sender, the 8-pin system connection is solely for the purposes of providing standardized wiring. It is particularly recommended if the
8-pin system connection at the receiver is used and the sender and receiver are connected to each other via a T-connector.
2)
If a sender does not have an additional guest connected to it, the extension connection has no function and must be sealed with a
protective cap.
3.2.18 Flexible control cabinet cabling and status indication on both sides
The safety light curtain can be connected to the control cabinet in different ways as
r
equired:
Separate connecting cables for sender and receiver
Separate connecting cables for sender and receiver with connection in the control
cabinet
Connection of sender and receiver via a T-connector, shared 5-pin or 8-pin con‐
necting cable to the control cabinet
3 P