7 Configuration
7.1 Overview
Important information
DANGER
Ris
k of ignition
Failure to observe this instruction can result in a risk of ignition from potential sparking
The IP enclosure rating only applies if the system plug is mounted.
If the system plug is not mounted, dirt, dust, or moisture may enter the device and
cause an explosion the next time the device is switched on.
b
Install the system plug outside the explosion-hazardous area.
b
Prevent the entry of dirt, dust, and moisture.
Table 24: Functions and their configuration type
Function Configuration type
Muting DIP switch
Partial blanking
Scanning range adjustment
Reduced resolution
Smart presence detection
Beam coding
Set to factory settings
Restart interlock Automatic configuration
External device monitoring (EDM)
Cascading
Status indication on both sides
The following system plugs are available for configuring via a DIP switch:
•
SP1 s
ystem plug
•
SP2 system plug
The SP1 system plug can be used on all of the senders and receivers of a single system
or on a host–guest system.
The SP2 system plug is only used on the receiver of a host system or single system. The
SP1 system plug is used on all other receivers of the guest systems and on all senders.
7 C
ONFIGURATION
84
O P E R A T I N G I N S T R U C T I O N S | deTec4 Ex II 3GD 8023872/18YZ/2021-01-14 | SICK