Function
On Off On On Partial blanking based on
exit monitoring with mut‐
ing signal 1 on system
connection In4 and mut‐
ing signal 2 on extension
connection In2
1)
2)
3)
1)
Muting hold time of 4 s.
2)
Muting end by ESPE active.
3)
Muting end delay of 200 ms.
Note on configuration
b
Chec
k the parity after setting the DIP switch, see "Checking the parity", page 94.
7.6 Configuring the scanning range
Important information
NOTE
T
he scanning range is only configured on the receiver of a single or host system.
DANGER
Incor
rect scanning width setting for dynamic protective field widths in the case of
devices with a resolution of 14 mm
Detection capability is no longer guaranteed. Persons and parts of the body to be
protected may not be detected.
b
In cases where the actual protective field width may be less than 1 m, configure
the dynamic protective field width (small range).
b
In cases where the actual protective field width is always at least 1 m, but may be
less than 2 m, configure the dynamic protective field width (medium range).
Prerequisites
•
SP2 s
ystem plug
Configuring the scanning range
T
he scanning range of the safety light curtain is configured using DIP switches 1 and 2
(row B) on the system plug of the receiver.
The scanning range configuration is taken on by all guest devices in a cascade.