LEDs Meaning
OSSD Field Diagnostics LEDs
1 2 3 4 5 6 7 8
O R
ed
O R
ed Ö Yel‐
low
Ö Yel‐
low
Ö Yel‐
low
o O Yel‐
low
o o o
The protective field is
int
errupted.
The muting hold time
was exceeded during exit
monitoring. The muting
sensors are no longer
engaged.
Make sure that the pro‐
tective field is clear again.
O R
ed
Ö Ö
R
ed/
yellow
Ö Yel‐
low
o o o O Yel‐
low
o o o
The protective field is
int
errupted.
The muting hold time was
exceeded during exit mon‐
itoring. One muting sensor
is still engaged.
Override required.
O R
ed
Ö Ö
R
ed/
yellow
o o Ö Yel‐
low
o O Yel‐
low
o o o
The protective field is
int
errupted.
The sensor gap monitor‐
ing has been exceeded.
Override required.
O R
ed
Ö Ö
R
ed/
yellow
Ö Yel‐
low
Ö Yel‐
low
o o O Yel‐
low
o o o
The protective field is
int
errupted.
The topmost beam was
interrupted during partial
blanking.
Override required.
O R
ed
Ö Ö
R
ed/
yellow
o Ö Yel‐
low
Ö Yel‐
low
o O Yel‐
low
o o o
The protective field is
int
errupted.
At least one muting sen‐
sor is engaged. The mut‐
ing condition is not met.
Override required.
O R
ed
Ö Ö
R
ed/
yellow
Ö Yel‐
low
o o Ö Yel‐
low
O Yel‐
low
o o o
The protective field is
int
errupted.
The total muting time was
exceeded.
Override required.
O R
ed
Ö Ö
R
ed/
yellow
o o Ö Yel‐
low
Ö Yel‐
low
O Yel‐
low
o o o
The protective field is
int
errupted.
The concurrence monitor‐
ing was exceeded.
Override required.
o LED of
f. Ö LED flashes. O LED illuminates. Empty cells mean that the LED lights up, flashes, or is off.
If front screen contamination increases in ongoing operation, the laser alignment aid switches on or the alignment
t
akes longer than 3 seconds, the receiver shows the alignment quality again.
Further topics
•
"Indic
ation of the alignment quality", page 106
•
"Diagnostic LEDs", page 115
OPERATION 9
8023872/18YZ/2021-01-14 | SICK O P E R A T I N G I N S T R U C T I O N S | deTec4 Ex II 3GD
111
Subject to change without notice