The SP2 system plug is only used on the receiver of a host system or single system. The
SP1 s
ystem plug is used on all other receivers of the guest systems and on all senders.
The system plugs are available in the following versions:
System plug with 5-pin system connection
System plug with 8-pin system connection
System plug with 5-pin system connection and 5-pin extension connection
System plug with 8-pin system connection and 5-pin extension connection
Prerequisites
T
he SP2 system plug can only be used with receivers that have the digit 1 at the
following position of their type code:
C4P-E*****1***
Use of system plugs in a single system and in a cascade
T
able 4: Use of SP1 system plug in a single system
SP1 system plug type code
1000 1200 1100 1300
Sender
1)
2)
1)
2)
Receiver
Be
am coding
Be
am coding
Restart inter‐
lock
External
device moni‐
toring
Application
diagnostic
output
Be
am coding
Restart inter‐
lock
External
device moni‐
toring
Application
diagnostic
output
IO-Link
Be
am coding
Restart inter‐
lock
External
device moni‐
toring
Application
diagnostic
output
IO-Link
SP1 system plug suitable.
1)
At the sender, the 8-pin system connection is solely for the purposes of providing standardized wiring. It
is par
ticularly recommended if the 8-pin system connection at the receiver is used and the sender and
receiver are connected to each other via a T-connector.
2)
If a sender does not have an additional guest connected to it, the extension connection has no function
and mus
t be sealed with a protective cap.
3 PRODUCT DESCRIPTION
18
O P E R A T I N G I N S T R U C T I O N S | deTec4 Ex II 3GD 8023872/18YZ/2021-01-14 | SICK
Subject to change without notice