Attribute ID Access rule Name Data type Description
Dec Hex
5 0x05 Get PowerOnCount UDINT Number of power-up processes until the
c
urrent error occurs
6 0x06 Get Errortype SHORT_STRING Error type (e.g. C1)
7 0x07 Get Errortext SHORT_STRING Error text as shown on the display
Services
•
G
et_Attribute_List
•
Get_Attributes_All
•
Get_Attribute_Single
13.6.2.2 Operating time object (0x401)
Object class
Attribute ID Access rule Name Data type
Dec Hex
1 0x01 Get Revision UINT
Services
•
G
et_Attribute_List
•
Get_Attributes_All
•
Get_Attribute_Single
Object instance
Attribute ID Access rule Name Data type Description
Dec Hex
1 0x01 Get Operating Time DATE_AND_TIME
(D
T)
If reference time is available: current time in
ms.
If reference time is not available: time since
device start in ms.
2 0x02 Get Start Time DATE_AND_TIME
(D
T)
Date and time during device start.
If reference time is not available: 0.
3 0x03 Get PowerOnCount UDINT Number of power-up processes
4 0x04 Get Flags UINT
•
Bit 0.0: T
ime stamps are based on the
network time. (If the time stamps are
based on device time, the value is
FALSE.)
•
Bit 0.1: time stamps are based on UTC.
(If the time stamps are based on an
operating hour counter or the time zone
cannot be clearly determined, the value
is FALSE.)
•
Bit 0.2: time stamps are exact. The value
is TRUE when the deviation from the
time of the network master is less than
the maximum deviation configured.
5 0x05 Get OperatingHours UDINT Operating hours of the device
Services
•
G
et_Attribute_List
•
Get_Attributes_All
•
Get_Attribute_Single
13 T
ECHNICAL DATA
176
O P E R A T I N G I N S T R U C T I O N S | microScan3 – EtherNet/IP™ 8020200/15ZT/2019-11-14 | SICK
Subject to change without notice