EasyManua.ls Logo

SICK microScan3 EtherNet/IP - Page 177

SICK microScan3 EtherNet/IP
212 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
13.6.2.3 Config info object (0x402)
Object class
Attribute ID Access rule Name Data type
Dec Hex
1 0x01 Get Revision UINT
Services
Get_Attribute_List
Get_Attributes_All
Get_Attribute_Single
Object instance
Attribute ID Access rule Name Data type Description
Dec Hex
1 0x01 Get DeviceName SHORT_STRING Device name
2 0x02 Get ApplicationName SHORT_STRING Application name
3 0x03 Get ProjectName SHORT_STRING Project name
4 0x04 Get UserName SHORT_STRING User name
5 0x05 Get ModificationTime DATE_AND_TIME
(D
T)
Time of the last change to the configuration
6 0x06 Get TransferTime DATE_AND_TIME
(DT)
Time of the last transmission of the configu‐
ration to the device
7 0x07 Get Reserved UDINT Reserved
8 0x08 Get AppChecksum UDINT Checksum (function)
9 0x09 Get OverallChecksum UDINT Checksum (function and network)
10 0x0A Get IntegrityHash STRUCT of Lower-level identification number of the
c
hecksums
MD5[0] UDINT
MD5[1] UDINT
MD5[2] UDINT
Reserved UDINT
Services
G
et_Attribute_List
Get_Attributes_All
Get_Attribute_Single
13.6.2.4 Device info object (0x403)
Object class
Attribute ID Access rule Name Data type
Dec Hex
1 0x01 Get Revision UINT
Services
G
et_Attribute_List
Get_Attributes_All
Get_Attribute_Single
TECHNICAL DATA 13
8020200/15ZT/2019-11-14 | SICK O P E R A T I N G I N S T R U C T I O N S | microScan3 – EtherNet/IP™
177
Subject to change without notice

Table of Contents

Related product manuals