2.7 Operational safety and specific hazards
Please observe the safety notes and the warnings listed here and in other sections
of this product documentation to reduce the possibility of risks to health and avoid
dangerous situations.
CAUTION
Optical radiation: Class 1 Laser Product
The accessible radiation does not pose a danger when viewed directly for up to 100
seconds. It may pose a danger to the eyes and skin in the event of incorrect use.
Do not open the housing. Opening the housing may increase the level of risk.
Current national regulations regarding laser protection must be observed.
Caution – Use of controls or adjustments or performance of procedures other than
those specified herein may result in hazardous radiation exposure.
It is not possible to entirely rule out temporary disorienting optical effects, particularly
in conditions of dim lighting. Disorienting optical effects may come in the form of
dazzle, flash blindness, afterimages, photosensitive epilepsy, or impairment of color
vision, for example.
WARNING
Electrical voltage!
Electrical voltage can cause severe injury or death.
Work on electrical systems must only be performed by qualified electricians.
The power supply must be disconnected when attaching and detaching electrical
connections.
The product must only be connected to a voltage supply as set out in the require‐
ments in the operating instructions.
National and regional regulations must be complied with.
Safety requirements relating to work on electrical systems must be complied with.
WARNING
Risk of injury and damage caused by potential equalization currents!
Improper grounding can lead to dangerous equipotential bonding currents, which may
in turn lead to dangerous voltages on metallic surfaces, such as the housing. Electrical
voltage can cause severe injury or death.
Work on electrical systems must only be performed by qualified electricians.
Follow the notes in the operating instructions.
Install the grounding for the product and the system in accordance with national
and regional regulations.
2.8 Norms and standards of functional safety management
The safety-related TiM361S 2D-LiDAR sensors fulfill the requirements of
EN ISO 13849-1:2015 regarding category B/PL b and the requirements of the follow‐
ing application standards:
EN ISO 13482:2014 – Robots and robotic devices – Safety requirements for
personal assistance robots
EN ISO 13855:2010 – Safety of machinery – Positioning of protective devices with
respect to the approach speeds of parts of the human body
DIN CLC/TS 62046:2009 – Safety of machinery – Application of protective equip‐
ment to detect the presence of persons