EasyManua.ls Logo

SICK TiM361S

SICK TiM361S
62 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Variant TiM361S
Power consumption 4W (typical), with unloaded digital outputs, incl. start-up current
Max. 16W with 4 loaded digital outputs
Input voltage Low: V
in
2V; I
in
0.3mA
High: 8V V
in
32V; 0.7mA I
in
5mA
Output voltage Low: 0V V
out
2V
High: (V
S
– 2V) V
out
V
S
; I
out
100mA
Electrical safety According to IEC 61010-1 (ed.3)
Housing Base part: Aluminum die cast
Optics cover: Polycarbonate with scratch-resistant coating
Housing color Yellow
Enclosure rating IP67 (IEC60529:1989+AMD1:1999+AMD2:2013), only valid with
closed “Aux interface” plastic cover
Protection class III (IEC61140:2016-1)
Weight 250g without connecting cables
Dimensions (L x W x H) 60mmx 60mmx 86mm
Contamination Contamination level 1, EN 61010-1 outside housing
Contamination level 3, EN 61010-1 outside housing, with sealed
USB connection
(All specifications regarding contamination do not apply to the
optics)
11.3 Safety-related parameters
Variant TiM361S
Category B (EN ISO 13849-1:2015)
Performance level PL b (ENISO13849-1:2015)
MTTF
D
(mean time to dan‐
gerous failure)
100years at 25°C ambient temperature (EN ISO 13849-1:2015)
1)
T
M
(mission time) 20years (EN ISO 13849-1:2015)
Conformities EN ISO 13849-1:2015, EN ISO 13482:2014,
EN ISO 13855:2010, ANSI/ITSDF B 56.5:2012
Safety-related detection
range
0.05m ... 4m; for 5% remission
Safety-related detection
capability
Up to a relative speed of 3.2m/s (max. speed of object = 1.6m/s
and max. speed of sensor = 1.6m/s) and at min. 5% remission:
Objects 40mm in diameter at a distance of 0.05m up to max.
1m
Objects 50mm in diameter at a distance of 0.05m up to max.
1.5m
Objects 70mm in diameter at a distance of 0.05m up to max.
2m
Objects 200mm in diameter at a distance of 0.05m up to max.
4m
Blind zone No objects are detected across the entire radial visual range
(scanning range of 270°) from the measurement origin up to a
distance of 0.05m
Response time
3)
Max. 2 scans: 134ms
4)
Protective field/Field eval‐
uation
1 analysis case with 1 field set and up to 3independent protective
fields, signaling of object detections in the protective fields via a
combination of 3PNP switching outputs (OUT1…OUT3)
11 TECHNICAL DATA
58
O P E R A T I N G I N S T R U C T I O N S | TiM361S 8022483/1LM2/2024-03-27 | SICK
Subject to change without notice