3. Delete the two field positions closest to the device.
4. Mark the two remaining field positions and shift them outside of the required
reference contour area.
5.
The button can switch to the configuration for the contour as reference field
start points.
The field starting points must lie between the scan line and the device so that the
scan line passes between the start and end points of the contour as reference
field.
6. Depending on the required shape of the reference contour field, create additional
field points between the device and the reference contour field. The distance
between the start and end points of the contour as reference field should be
approximately 20cm.
The button can be used to switch between the start and end points of the contour
as reference field for editing purposes. The active points are highlighted in light green
while the deactivated points are dark green.
6.7 Digital inputs/outputs
The device has the following safety-related interfaces, the statuses of which only
become valid after operational readiness is reached (see also Operating modes/opera‐
tional statuses):
6.7.1 Digital inputs
The device has 4 PNP digital inputs (IN 1-4), which by means of selecting the corre‐
sponding binary combination (see the following table), activate one of the 16 available
field data sets, and therefore the active protective fields.
IN X
INGND
GND
GND
U
V
C
B
A
D
U
V
= DC 9 V ... 28 V
U
e
U
e
= max. 32 V
U
V
6,64 K
3,32 K
TiMxS
U
V
U
V ext
GND
GND
Figure 8: Configuration and switching principle of the IN1, IN2, IN3, IN4 inputs
Field set factory settings – digital inputs:
Field set Digital inputs
IN 1 IN 2 IN 3 IN 4
1 0 0 0 0
2 1 0 0 0
3 0 1 0 0
4 1 1 0 0
5 0 0 1 0
6 1 0 1 0
7 0 1 1 0
COMMISSIONING AND CONFIGURATION 6
8022483/1LM2/2024-03-27 | SICK O P E R A T I N G I N S T R U C T I O N S | TiM361S
37