The enclosure rating stated in the technical data is achieved only with screwed plug
connectors or protective caps.
Protect the device from dust and moisture when the plastic USB cover is open.
The USB interface is only for parameterization. Remove the USB cable for problem-free
operation of the device.
All circuits connected to the device must be configured as SELV or PELV circuits. SELV =
safety extra-low voltage, PELV = protective extra-low voltage.
Protect the device with an external 0.8A slow-blow fuse at the beginning of the supply
cable.
Connect the connecting cables in a de-energized state. Do not switch on the supply
voltage until installation is complete and all connecting cables are connected to the
device and control.
Wire cross-sections in the supply cable from the customer’s power system must be
implemented in accordance with the applicable standards.
6.4 Installation of SOPAS Engineering Tool
6.4.1 System requirements for SOPASET
System Minimum requirement for version 3.3.3
CPU Standard Intel Pentium computer or compatible, at minimum Pen‐
tiumIII 500MHz
Frequency and working
memory
Min. 1GHz/1GB RAM
Interface USB 2.0 or compatible
Operating system Windows XP, Vista, Windows 7 or Windows 8 (32/64bit)
Minimum resolution 1024 x 768px
Memory At least 450MB
6.4.2 Installation process
NOTE
Use the standard version of the software, not the portable version. Using the standard
version ensures that all SOPASET functions and drivers are available. For installation, it
may also be necessary to have administrator authorizations.
•
Select the installation language.
This selection only determines the language of the installation wizard. Regardless of the
selected installation language, all SOPASET languages can be selected subsequently.
•
Chose whether you want to have an icon on the desktop or on the Start Menu bar,
and click Next >.
•
Select the installation location for SOPASET.
It is recommended not to change the suggested location.
•
Click Next >.
The installation process starts. Please wait until it is fully complete and the next page
appears. The Run SOPAS Engineering Tool checkbox is preselected.
•
Use the Close button to complete the installation and launch SOPASET.