Variant TiM361S
Protective field width Minimum protective field width ≥0.3m
Protective field tolerance +100mm; 0.66° acc. to IEC62046 at 5% remission
Temperature drift: 1.5mm/Kelvin
Number of field sets 16 field sets with 3 independently configurable protective fields
each
Digital inputs PNP inputs: 4 x IN, IN1… IN4, (U
e
= max. 28V, I
e
= max. 5mA),
opto-decoupled, debounce approx. 10ms
Digital outputs PNP outputs: 4x OUT, OUT1 … OUT4, (each I
a
max. 100mA),
not electrically isolated from supply voltage, short-circuit pro‐
tected/temperature protected
Adjustable for OUT 1 .... OUT 3:
Response time (134ms ... 30s)
Holding time (0ms ... 600s)
5)
1)
At higher ambient temperatures, the MTTF
D
value decreases according to the Arrhenius equation. These
values can be requested from SICK.
2)
In safety-related detection zone
3)
Response of the digital outputs when an object is detected with the smallest response time that can be
set and the filter deactivated, see "Default configuration", page 29.
4)
At +45° to +225° of the working range; max. 150ms at -45° to +45° of the working range (see figure 2,
page 17)
5)
The device has an internal, system-related time delay of 67ms
Note
The product is intended for use indoors. It is not suitable for use in special surround‐
ings (e.g., radiation and sparks from welding systems, strong sources of infrared, ther‐
mal convection, fluorescent and stroboscopic light sources, snow, rain, contamination)
or must yet be made suitable, if applicable.
11.4 Performance
Variant TiM361S
Response time Typ. 1scan: 67ms
Max. 2 scans: 134ms
1)
Operational readiness ≥1min
Integrated application Protective field evaluation with flexible fields
Protective field tolerance 100mm, 0.66° (IEC 62046, at 5% remission)
Number of field sets 16 triple fields (48 protective fields)
Simultaneous evaluation
cases
3 simultaneous protective fields (per field set)
Filter Edge filter
Particle filter
Average filter
1)
Corresponds to max. 134ms between +45° and +225° of the working range, max. 150ms between
-45° and +45° of the working range (see figure 2, page 17)
11.5 Interfaces
Variant TiM361S
USB Type: Micro-USB
Length of cable: max. 3m
Function: Parameterization