Field set Digital inputs
IN 1 IN 2 IN 3 IN 4
8 1 1 1 0
9 0 0 0 1
10 1 0 0 1
11 0 1 0 1
12 1 1 0 1
13 0 0 1 1
14 1 0 1 1
15 0 1 1 1
16 1 1 1 1
Characteristic data of the digital inputs:
The characteristic data is identical for of all digital inputs.
Switching behavior Current to the input starts the assigned function in the device.
Default: “active high” level, 10ms debounce
Properties Opto-decoupled
Switchable with an electronic switch (PNP output) or mechanical
switch
PNP electrical values see "Mechanics/electronics", page 57
6.7.2 Digital outputs
Infringement of the respective protective field is displayed in the active field data set by
means of 3 available PNP digital outputs (OUT1…OUT3).
The factory setting for the digital outputs is the status “Field 1, 2, and 3 infringed”.
Figure 9: Configuration and switching principle of the OUT1, OUT2, OUT3 outputs
1
With an inductive load: Sweep-out circuit – attach a freewheeling diode directly to the
load!
Table 2: Assignment of infringed fields – digital outputs:
Fields of a field set Digital outputs
OUT 1 OUT 2 OUT 3
Fields 1, 2, and 3
infringed
Active Active Active