11 Technical data
NOTE
The relevant online product page for your product, including technical data, dimensional
drawing, and connection diagrams, can be downloaded, saved, and printed from the
Internet.
The product page can be accessed via the SICK ProductID: pid.sick.com/{P/N}/{S/N}
{P/N} corresponds to the part number of the product, see type label.
{S/N} corresponds to the serial number of the product, see type label (if indicated).
Please note: This documentation may contain further technical data.
11.1 Features
Variant TiM361S
Measurement principle HDDM (lower statistical error)
Application Indoor
Light source Infrared (wavelength 850nm, max. pulse power 880mW, max.
pulse width 5ns, pulse frequency 1,500kHz)
Laser class 1(IEC60825-1:2014, EN60825-1:2014+A11:2021)
Complies with 21 CFR 1040.10 and 1040.11 except for conform‐
ance with IEC 60825-1 Ed.3., as described in Laser Notice No.56
dated 8May2019.
Aperture angle 270° (horizontal)
Scan field flatness
1)
±1.5°
Scanning frequency 15Hz
Angular resolution 0.33°
Workspace 0.05m... 10m
Safety-related working
range
0.05m... 4m (at 5% remission)
Blind zone 0.00m... 0.05m
Sensing range for 10%
remission
8m (typical)
2)
Minimum physical object
sizes (cross-section)
169mm at a distance of 8m
88mm at a distance of 4m
47mm at a distance of 2m
At respective radiance factor
Distance resolution 1mm
Spot size Spot size on the optics cover: 7mm
Divergence: 8.6mrad (0.49°)
Number of echoes evalu‐
ated
1
1)
Reference area for base of housing
2)
at ambient temperature < -15°C: typ. 7.5m
11.2 Mechanics/electronics
Variant TiM361S
Electrical connection 1 x voltage supply connection, 12-pin M12 male connector
1 x micro USB female connector, type B
Supply voltage 9VDC... 28VDC, SELV and PELV according to IEC60364-4-41
TECHNICAL DATA 11
8022483/1LM2/2024-03-27 | SICK O P E R A T I N G I N S T R U C T I O N S | TiM361S
57
Subject to change without notice