WARNING
Risk of ineffectiveness of the protective device!
•
After parameterizing the device or subsequently modifying the parameters, the
effectiveness of the protective device in the application must be reviewed and
documented. For a safety-related use of the device, this may in certain circumstan‐
ces include a comprehensive safety assessment.
NOTE
The parameterization and commissioning in the case of a safety-related use of the
device must only be performed by appropriately qualified personnel. This applies in
particular to settings that differ from the default parameterization, and the resultant
requirement for an assessment of the safety-related sensor function within the applica‐
tion.
6.5.6.1 Edge filter, particle filter, , moving average filter
Default: All filters “inactive”
NOTICE
Adherence to the safety-related technical data listed in section see "Safety-related
parameters", page 58 can only be ensured when the filters are deactivated. The
activation or use of filters in a safety-related context can therefore only be made
possible by an additional safety verification for the specific use case or the specific
overall system; this safety verification must be kept separately by the user.
The filters should be deactivated, otherwise objects that appear sporadically and for a
short time will not be detected and/or filtered out.
The filters can also delay the response of the digital outputs.
6.5.6.2 Hold time of outputs
Default: Maximum duration time of the outputs (8,956scans/600,052ms)
6 COMMISSIONING AND CONFIGURATION