Working range
0
Scanning range in m (feet)
Scanning range in m (feet)
0
6
(19.69)
6
(19.69)
2
(6.56)
2
(6.56)
2
(6.56)
2
(6.56)
6
(19.69)
10
(32.81)
14
(45.93)
10
(32.81)
14
(45.93)
6
(19.69)
14
(45.93)
14
(45.93)
10
(32.81)
10
(32.81)
Range for not safety-related detection:
0.05 m to max. 10 m (32.81 feet)
Range for safety-related detection:
0.05 m to max. 4 m (13.21 feet)
180°
‒45°
225°
270°
90°
Attention! From the measurement origin up to a distance of
0.05 m (0.17 feet) no objects are detected (blind zone!) over
the entire radial field of view (scanning range of 270°).
1
2
3
4
5
Figure 2: TiM361S working range diagram, decimal separator: period
1
Scanning range in meters (feet)
2
Scanning range in meters (feet)
3
Scanning range for non safety-related detection: 0.05m to max. 10m
4
Scanning range for safety-related detection: 0.05m to max. 5m
5
WARNING! No objects will be detected within a range of 0.05m from the measurement
origin and across the entire radial field of view (scanning range of 270°) (blind zone!).
3.8 Object sizes
As the distance from the device increases, the laser beam expands. As a result, the
diameter of the light spot on the surface of the object increases.
1
2
Figure 3: Beam expansion
1
Expanded laser beam
2
Optical axis
Required values for calculating the light spot size and minimum object size:
Light spot size on the device cover: 7mm (rounded up)
Light spot divergence per single pulse: 0.49deg (8.6mrad)
supplement (1 measured value consists of several overlapping single pulses):
PRODUCT DESCRIPTION 3
8022483/1LM2/2024-03-27 | SICK O P E R A T I N G I N S T R U C T I O N S | TiM361S
17
Subject to change without notice