After deleting the field points, the corresponding outputs for signaling object detections
in the protective fields will be active (active low) until they are actively changed.
When the field points are deleted, the field editor will not display any protective fields!
6.6
Editing protective fields
Figure 7: Device window: Parameters - detection fields (evaluation fields)
The user can change parameters in the right part of the window. SOPAS immediately
transfers these changes to the device (default setting).
However, detection fields that have been changed in size and shape must always be
manually transferred to the device using the button. All changed parameters are only
temporarily stored in the device for the time being and are not stored on the computer.
To optimize the dimensions of the detection fields:
COMMISSIONING AND CONFIGURATION
6