Fields of a field set Digital outputs
OUT 1 OUT 2 OUT 3
Fields 2 and 3
infringed
Deactivated Active Active
Field 3 infringed Deactivated Deactivated Active
All fields free Deactivated Deactivated Deactivated
Active: in working position; deactivated: in resting position
Initial level:
The level of the PNP switching outputs OUT1…OUT3 is “active low” (deactivated status,
resting position: high, working position: low i.e. field infringed).
All fields of a field set are considered infringed upon switching on, booting, in the event
of an error and when the device is switched off.
PNP switching output 4 works with the following levels:
Function Level
Device Ready High
Index signal (15Hz), cor‐
responds to measurement
at 90°
Low peaks
Fault Low
6.7.3 Characteristic data of the digital outputs
PNP switching
behavior
PNP switching to supply voltage U
v
.
•
OUT1…OUT3:
Resting level high (no object detection),
Working level low (object detection)
Response time 134ms…30s (configurable via SOPASET),
Duration time: 0ms…600s (configurable via SOPASET)
•
OUT4:
Resting level: high (Device Ready),
Working level: low (error), low-impulse (15Hz, index, corresponds to
measurement at 90°)
Properties Short-circuit protected and temperature protected
Not electrically isolated from supply voltage U
v
PNP electrical val‐
ues
see "Mechanics/electronics", page 57
NOTE
Longer connecting cables at the digital outputs of the device should be avoided due to
the resulting fall in voltage. This is calculated as follows:
ΔU = 2 x length x current/conductance value x cross-section
Conductance value for copper: 56m/Ωmm
2
6.8 Function and status displays
COMMISSIONING AND CONFIGURATION 6
8022483/1LM2/2024-03-27 | SICK O P E R A T I N G I N S T R U C T I O N S | TiM361S
39