Variant TiM361S
Digital inputs 4 (PNP, for field switching)
Digital outputs 3 (PNP, for displaying an object detection in the protective fields),
additional 1x “Device Ready”
Optical indicators 2 LEDs (on, “device ready”)
11.6 Ambient data
Variant TiM361S
Electromagnetic compati‐
bility (EMC)
Radiation emitted: Residential area
(EN 61000-6-3:2007+AMD:A1:2011)
Electromagnetic immunity: Industrial environment
(EN 61000-6-2: 2005)
Vibration resistance Sine resonance scan:
10Hz ... 1,000Hz
(IEC 60068-2-6:2007)
Sine test:
10Hz ... 500Hz; 5g; 10 frequency cycles
(IEC 60068-2-6:2007)
Noise test:
10 … 250Hz; 4.24grms, 5h
(IEC 60068-2-64:2008)
Shock resistance 50g; 11ms; 6shocks/axis
25g; 6ms; 2,000shocks/axis
50g; 3ms; 10,000shocks/axis
(IEC60068-2-27:2008)
Ambient temperature Commissioning/switching on: –10°C... +50°C
Operation: –25°C... +50°C
Storage: –40°C... +75°C
(IEC 60068-2-14:2009)
Ambient humidity Operation: ≤80%, non-condensing
Storage: ≤ 95%, non-condensing
(EN 60068-2-30:2005)
Ambient light immunity 3,000lx (direct exposure)
60,000lx (indirect exposure)
Altitude <2,900m above sea level
damp heat +25°C ... +55°C, 95% r.h., 6 cycles
(EN 60068-2-30:2005)
temperature change -25°C … +50°C, 10 cycles
(EN 60068-2-14:2009)
11 TECHNICAL DATA
60
O P E R A T I N G I N S T R U C T I O N S | TiM361S 8022483/1LM2/2024-03-27 | SICK
Subject to change without notice