EasyManua.ls Logo

SICK TiM361S

SICK TiM361S
62 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Variant TiM361S
Digital inputs 4 (PNP, for field switching)
Digital outputs 3 (PNP, for displaying an object detection in the protective fields),
additional 1x “Device Ready”
Optical indicators 2 LEDs (on, “device ready”)
11.6 Ambient data
Variant TiM361S
Electromagnetic compati‐
bility (EMC)
Radiation emitted: Residential area
(EN 61000-6-3:2007+AMD:A1:2011)
Electromagnetic immunity: Industrial environment
(EN 61000-6-2: 2005)
Vibration resistance Sine resonance scan:
10Hz ... 1,000Hz
(IEC 60068-2-6:2007)
Sine test:
10Hz ... 500Hz; 5g; 10 frequency cycles
(IEC 60068-2-6:2007)
Noise test:
10 … 250Hz; 4.24grms, 5h
(IEC 60068-2-64:2008)
Shock resistance 50g; 11ms; 6shocks/axis
25g; 6ms; 2,000shocks/axis
50g; 3ms; 10,000shocks/axis
(IEC60068-2-27:2008)
Ambient temperature Commissioning/switching on: –10°C... +50°C
Operation: –25°C... +50°C
Storage: –40°C... +75°C
(IEC 60068-2-14:2009)
Ambient humidity Operation: ≤80%, non-condensing
Storage: 95%, non-condensing
(EN 60068-2-30:2005)
Ambient light immunity 3,000lx (direct exposure)
60,000lx (indirect exposure)
Altitude <2,900m above sea level
damp heat +25°C ... +55°C, 95% r.h., 6 cycles
(EN 60068-2-30:2005)
temperature change -25°C … +50°C, 10 cycles
(EN 60068-2-14:2009)
11 TECHNICAL DATA
60
O P E R A T I N G I N S T R U C T I O N S | TiM361S 8022483/1LM2/2024-03-27 | SICK
Subject to change without notice

Table of Contents