&RQILJXULQJ
S7-300 Automation System, Hardware and Installation: CPU 31xC and CPU 31x
5-24 A5E00105492-03
5XOH*URXQGWKHFDEOHVKLHOGLQJ
You should always connect both ends of the cable shielding to ground/functional
ground, since this is the only way to achieve good interference suppression in the
higher frequency range.
If you connect only one end of the shielding (that is, at one or the other end of the
cable) to ground, you will merely achieve an attenuation in the lower frequency
range. One-sided shielding connections could be more favorable in situations
not allowing the installation of an equipotential bonding conductor,
if analog signals (some mA or µA) are transmitted,
or if foil shielding is used (static shielding).
1RWH
Potential differences between two grounding points might cause an
equipotential current flow across shielding connected at both ends. In this case
you should install an additional equipotential bonding conductor..
&DXWLRQ
Always avoid the flow of operating current to ground.
'HWDLOVRQFDEOHVKLHOGLQJDQGHTXLSRWHQWLDOERQGLQJ
are found in the Appendix under the same topic.
5XOH*URXQGWKHORDGFLUFXLWV
You should always ground the load circuits. This common reference potential
(earth) ensures proper functioning.
7LSQRWYDOLGIRU&38[&:
If you want to locate a fault to ground, provide your load power supply (Terminal L-
or M) or the isolating transformer with a removable connection to the protective
conductor (see 2YHUYLHZ*URXQGLQJNumber 4).

Table of Contents

Other manuals for Siemens CPU 313C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens CPU 313C and is the answer not in the manual?

Siemens CPU 313C Specifications

General IconGeneral
MPI InterfaceYes
Number of digital inputs24
Number of digital outputs16
Number of analog inputs4
Number of analog outputs2
Supply voltage24 V DC
High-speed countersYes
Bit Operations Execution Time0.1 µs
Word Operations Execution Time0.2 µs
Power Consumption5 W
Dimensions (W x H x D)40 x 125 x 130 mm
Operating Temperature0 to 60 °C
Communication InterfacesMPI
Programming LanguagesLAD, FBD, STL
Product type designationCPU 313C
Weight490 g

Related product manuals