2.2 Qualified Personnel
Only suitably qualified personnel may operate or perform maintenance on the Maxum II. For
the purposes of safety, qualified personnel are defined as follows:
Those who have been appropriately trained for the tasks which they are performing (for
example, commissioning, maintenance, or operation).
Those who have been appropriately trained in the operation of the Maxum II process gas
chromatograph and are sufficiently acquainted with Maxum II documentation.
Those who are familiar with the safety concepts of the Maxum II process gas
chromatograph and are sufficiently acquainted with Maxum II documentation.
Those who are authorized to energize, ground, and tag circuits and devices in accordance
with established safety practices may perform those tasks for which they are trained.
WARNING
Avoid injury and property damage
Operation or Maintenance of the Maxum II by unqualified personnel or failure to observe the
warnings in this manual or on the device may lead to severe personal injury and/or extensive
property damage.
WARNING
Do not connect analyzer to the internet.
This equipment must not be connected to the internet except by a secure connection using
a network security appliance administered by qualified IT personnel.
Failure to implement robust network security may expose your company to internet hacking
attacks that could result in theft or loss of sensitive data, equipment damage, serious injury
or death.
For more information see the Maxum II Explosion Protection Safety Standards Manual
(A5E02220442001) at Maxum II Explosion Protection Safety Standards Manual (https://
support.industry.siemens.com/cs/document/42017542/maxum-edition-ii%3A-explosion-
protection-safety-standards?dti=0&pnid=17741).
Safety notes
2.2 Qualified Personnel
Maxum edition II Analyzer General Maintenance
8 Manual, August 2018, A5E42019842001

Table of Contents

Other manuals for Siemens Maxum II

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens Maxum II and is the answer not in the manual?

Siemens Maxum II Specifications

General IconGeneral
CategoryGas Chromatograph
Measurement PrincipleGas Chromatography
Communication ProtocolsModbus, Ethernet, Profibus
Operating Temperature-20°C to 55°C
Power Supply24 VDC or 100-240 VAC
Mountingrack mount
ApplicationsRefinery, chemical, petrochemical, natural gas
DetectorsThermal Conductivity Detector (TCD), Flame Ionization Detector (FID)
Sample InletsMultiple
DimensionsVaries by configuration (e.g., 19" rack mount)

Related product manuals