Page 52 Milltronics BW100 - INSTRUCTION MANUAL 7ML19985DJ01
mmmmm
Parameters
P018  Speed Constant Adjust 
This parameter allows adjustment to the speed constant (P015). 
Initially, this parameter displays the dynamic speed of the belt. If the displayed speed is 
not equal to the actual speed, enter the actual belt speed. 
For speed sensor applications, the value of P015 is automatically adjusted. 
For constant speed (TB1 5/6 jumper) the value of P014 is automatically adjusted. 
P019  Manual Span Adjust 
This parameter allows adjustment to the span calibration. 
The adjustment value is generally determined by performing material tests. Refer to 
Recalibration/Material Tests, 
page 30. 
Enter the calculated adjustment.
P022  Minimum Speed Frequency 
Sets the minimum frequency that the speed sensor can reliably read. Signals at low 
frequencies are erratic, adversely affecting the performance of the weighing system. 
Entry: 
1 = 1 Hz (at 1 Hz, it takes 1 sec before defaulting to 0 speed)
2 = 2 Hz (at 2 Hz, it takes 0.5 sec before defaulting to 0 speed)
P080 Damping 
Sets the speed of response to which the displayed readings (rate, load and speed), and 
outputs (alarm and mA) react to change. 
The greater the damping value, the slower the response. 
Enter damping value, range 1 - 9999.
P081 Display Mode 
Sets the display mode. Normally, the display shows rate, or the last manually selected 
function. If set to alternating, the display alternates between rate and totalizer (1 and/or 
2, as programmed by P647). 
Entry:
0 = normal 
1 = alternating 
Note: The effect of damping (P080) on mA output can be overridden by mA output 
damping (P220).