Technical specifications
8.1 X-300 technical specifications
SCALANCE X-300
Operating Instructions, 10/2010, A5E01113043-10
149
Table 8- 6 Electrical data part 2
Type Current consumption
at 24 VDC rated voltage
Overcurrent protection at input:
Non-replaceable fuse
X304-2FE 260 mA 3 A / 32 V
X306-1LD FE 200 mA 3 A / 32 V
X307-3 400 mA 3 A / 32 V
X307-3LD 400 mA 3 A / 32 V
X308-2 400 mA 3 A / 32 V
X308-2LD 400 mA 3 A / 32 V
X308-2LH 400 mA 3 A / 32 V
X308-2LH+ 400 mA 3 A / 32 V
X310 400 mA 3 A / 32 V
X310FE 400 mA 3 A / 32 V
X320-1 FE 400 mA 3 A / 32 V
X320-3LD FE 500 mA 3 A / 32 V
Table 8- 7 Signaling contact
Type Voltage at signaling contact Current through signaling contact
X304-2FE 24 VDC max. 100 mA
X306-1LD FE 24 VDC max. 100 mA
X307-3 24 VDC max. 100 mA
X307-3LD 24 VDC max. 100 mA
X308-2 24 VDC max. 100 mA
X308-2LD 24 VDC max. 100 mA
X308-2LH 24 VDC max. 100 mA
X308-2LH+ 24 VDC max. 100 mA
X310 24 VDC max. 100 mA
X310FE 24 VDC max. 100 mA
X320-1 FE 24 VDC max. 100 mA
X320-3LD FE 24 VDC max. 100 mA
Table 8- 8 Electrical data: Transmitter output optical and receiver input
Transmitter output optical Receiver input Type
min.
[dBm]
max.
[dBm]
Sensitivity min. [dBm] max. input power
[dBm]
X304-2FE -19 -14 -32 -3
X306-1LD FE -15 -8 -34 -3
X307-3 -9.5 -4 -17 -3
X307-3LD -9.5 -3 -21 -3
X308-2 -9.5 -4 -17 -3
X308-2LD -9.5 -3 -21 -3
X308-2LH -6 0 -23 -3