EasyManuals Logo

Siemens SCALANCE X-300 Series Manual

Siemens SCALANCE X-300 Series
290 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #237 background imageLoading...
Page #237 background image
Approvals, certificates, standards
9.7 Product group XR-300M PoE
SCALANCE X-300
Operating Instructions, 10/2010, A5E01113043-10
237
cULus Approval for Industrial Control Equipment
Only the device version with the 200 to 240 V AC power supply has the cULus Ind. Cont. Eq.
approval.
cULus Listed IND. CONT. EQ.
Underwriters Laboratories Inc. complying with:
UL 508
CSA C22.2 No. 142-M1987
9.7.2 X-300M PoE declaration of conformity
Declaration of conformity
You will find the EC Declaration of Conformity for these products on the Internet at the
following address:
10805878
> Entry list
> Entry type "Certificates"
> Certificate type "Declaration of Conformity"
Example German: "EG-Konformitätserklärung SCALANCE X310",
Example English: "Declaration of Conformity SCALANCE X310".
9.7.3 XR-300M PoE mechanical stability in operation
The switch meets the following requirements for mechanical stability:
IEC 60068-2-6 (vibration)
Individual mounting: (2-point mounting:)
10 to 58 Hz: 0.075 mm
85 – 150 Hz: 1 g
1 octave/min, 20 sweeps
Mounting in the rack (4-point mounting):
5 to 8.51 Hz: 3.5 mm
8.51 – 500 Hz: 1 g
1 octave/min, 20 sweeps
IEC 60068-2-27 (shock)
Mounting in the rack (2-point mounting):
15 g, 11 ms duration, 6 shocks per axis

Table of Contents

Other manuals for Siemens SCALANCE X-300 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE X-300 Series and is the answer not in the manual?

Siemens SCALANCE X-300 Series Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE X-300 Series
CategorySwitch
LanguageEnglish

Related product manuals