Technical specifications
8.2 X-300M technical specifications
SCALANCE X-300
Operating Instructions, 10/2010, A5E01113043-10
155
Table 8- 16 Construction
Device:
SCALANCE
(Variant) Dimensions (W x H x D)
[in mm]
Weight
[in g]
IP degree of
protection
X308-2M (-) 120 x 125 x 124 1400 IP20
Table 8- 17 Installation options
Installation options: Device:
SCALANCE
(Variant)
DIN rail S7-300 standard rail Wall 19" rack
X308-2M (-) ● ● ● -
*) Note: When used in shipbuilding, installation on a 35 mm DIN rail is not permitted. In ships, the 35 mm DIN rail does not provide
adequate support.
Table 8- 18 Permitted ambient conditions
Device:
SCALANCE
(Variant) Storage/transportation
temperature
Relative humidity at 25
°C during operation,
maximum
Operating altitude at
max. xx °C ambient
temperature
X308-2M (-) -40 °C through +70 °C ‹ 95 %
(no condensation)
2000 m at max. 56 °C
3000 m at max. 50 °C
CAUTION
The permitted operating temperature is decided by the entire device (modular device (M)
fitted with modules).
The modular devices (M) are devices with a modular design and the inserted modules are
an integral part of the modular device (M).
As a result, the properties of the MM900 media modules and the SFP transceivers decide
the permitted operating temperatures of the entire device (modular device (M) fitted with
modules).
The following table shows the X308-2M.
WARNING
Horizontal mounting position/installation of the X308-2M
When using the SFP transceivers (in the specified temperature range, see technical
specifications) only horizontal installation is permitted.
Vertical mounting position/installation of the X308-2M reduces the maximum permitted
ambient temperature
If the device is installed in the vertical position, the maximum permitted ambient
temperature is reduced to +50 °C.