Technical specifications
8.7 SFP technical specifications
SCALANCE X-300
Operating Instructions, 10/2010, A5E01113043-10
185
Modular installation options:
Device:
Transceiver
(Variant)
Media module installation in slot SFP installation in SFP media module
SFP991-1LH+ (1 x 100 Mbps, LC port optical, single
mode glass, up to max. 70km)
-
SFP992-1 (1 x 1000 Mbps, LC port optical,
multimode glass, up to max. 750m)
-
SFP992-1LD (1 x 1000 Mbps, LC port optical,
single mode glass, up to max. 10km)
-
SFP992-1LH (1 x 1000 Mbps, LC port optical,
single mode glass, up to max. 40km)
-
SFP992-LH+ (1 x 1000 Mbps, LC port optical,
single mode glass, up to max. 70km)
-
SFP992-1ELH (1 x 1000 Mbps, LC port optical,
single mode glass, up to max. 120km)
-
*) Note: When used in shipbuilding, installation on a 35 mm DIN rail is not permitted. In ships, the 35 mm DIN rail does not provide
adequate support.
Table 8- 88 Permitted ambient conditions
Device:
transceiver
(Variant) Operating
temperature
Storage/
transport
temperature
Relative humidity at
25 °C during
operation, maximum
Operating altitude at
max. xx °C ambient
temperature
SFP991-1 (1 x 100 Mbps, LC port optical,
multimode glass, up to max. 3 km)
-40 °C through
+85 °C
-40 °C to
+85 °C
‹ 95 %
(no condensation)
2000 m at max. 56 °C
3000 m at max. 50 °C
SFP991-1LD (1 x 100 Mbps, LC port optical, single
mode glass, up to max. 26 km)
-40 °C through
+85 °C
-40 °C to
+85 °C
‹ 95 %
(no condensation)
2000 m at max. 56 °C
3000 m at max. 50 °C
SFP991-1LH+ (1 x 100 Mbps, LC port optical, single
mode glass, up to max. 70km)
-40 °C through
+85 °C
-40 °C to
+85 °C
‹ 95 %
(no condensation)
2000 m at max. 56 °C
3000 m at max. 50 °C
SFP992-1 (1 x 1000 Mbps, LC port optical,
multimode glass, up to max. 750m)
-40 °C through
+85 °C
-40 °C to
+85 °C
‹ 95 %
(no condensation)
2000 m at max. 56 °C
3000 m at max. 50 °C
SFP992-1LD (1 x 1000 Mbps, LC port optical, single
mode glass, up to max. 10km)
-40 °C through
+85 °C
-40 °C to
+85 °C
‹ 95 %
(no condensation)
2000 m at max. 56 °C
3000 m at max. 50 °C
SFP992-1LH (1 x 1000 Mbps, LC port optical, single
mode glass, up to max. 40km)
-40 °C through
+85 °C
-40 °C to
+85 °C
‹ 95 %
(no condensation)
2000 m at max. 56 °C
3000 m at max. 50 °C
SFP992-LH+ (1 x 1000 Mbps, LC port optical, single
mode glass, up to max. 70km)
-40 °C through
+85 °C
-40 °C to
+85 °C
‹ 95 %
(no condensation)
2000 m at max. 56 °C
3000 m at max. 50 °C
SFP992-1ELH (1 x 1000 Mbps, LC port optical, single
mode glass, up to max. 120km)
-40 °C through
+85 °C
-40 °C to
+85 °C
‹ 95 %
(no condensation)
2000 m at max. 56 °C
3000 m at max. 50 °C