Technical specifications
8.7 SFP technical specifications
SCALANCE X-300
Operating Instructions, 10/2010, A5E01113043-10
187
Note
Signaling contact and media modules
The SFP transceivers do not have a signaling contact. The signaling contact is on the
modular device (M).
Table 8- 91 Electrical data: Transmitter output optical and receiver input
Transmitter output optical Receiver input Device:
Transceiver
(Variant)
min.
[dBm]
max.
[dBm]
Sensitivity min.
[dBm]
max. input power
[dBm]
SFP991-1 (1 x 100 Mbps, LC port
optical, multimode glass, up
to max. 3 km)
-19 -14 -32 -3
SFP991-1LD (1 x 100 Mbps, LC port
optical, single mode glass,
up to max. 26 km)
-15 -8 -34 -3
SFP991-1LH+ (1 x 100 Mbps, LC port
optical, single mode glass,
up to max. 70km)
-5 0 -34 -3
SFP992-1 (1 x 1000 Mbps, LC port
optical, multimode glass, up
to max. 750m)
-9.5 -4 -17 -3
SFP992-1LD (1 x 1000 Mbps, LC port
optical, single mode glass,
up to max. 10km)
-9.5 -3 -21 -3
SFP992-1LH (1 x 1000 Mbps, LC port
optical, single mode glass,
up to max. 40km)
-6 0 -23 -3
SFP992-LH+ (1 x 1000 Mbps, LC port
optical, single mode glass,
up to max. 70km)
0 5 -23 -3
SFP992-1ELH (1 x 1000 Mbps, LC port
optical, single mode glass,
up to max. 120km)
0 5 -32 -8