Network topologies
3.4 Options of media redundancy
SCALANCE X-300
38 Operating Instructions, 10/2010, A5E01113043-10
Topology
The following schematic shows a possible topology for devices in a ring with MRP.
10
9
8
7
6
5
4
3
2
1
5HGXQGDQF\GRPDLQ
+0,VWDWLRQ
(QJLQHHULQJVWDWLRQ
(76
(70
(7SUR
6ZLWK&3$GYDQFHG
6&$/$1&(;VZLWFK
3&ZLWK&3
6ZLWK&3$GYDQFHG
Figure 3-6 Example of a ring topology with the MRP media redundancy protocol
The following rules apply to a ring topology with media redundancy using MRP:
All the devices connected within the ring topology are members of the same redundancy
domain.
One device in the ring is acting as redundancy manager.
All other devices in the ring are redundancy clients.
Non MRP-compliant devices can be connected to the ring via a SCALANCE X switch or via
a PC with a CP 1616.
Note
SCALANCE X-300 - modular devices (M)
Remember that in the modular switches the ring ports are located on MM900 media
modules.