Description
3.4 Function
SIMATIC Box PC 627
Operating Instructions, Release 05/2006, A5E00362052-03
3-3
3.4 3.4 Function
• Integrated configurable monitoring functions (program execution (watchdog) for internal
housing temperature, processor temperatures, disk drive temperatures and RPM of the
two fans)
• Enhanced diagnostics / messaging via Ethernet, e-mail, SMS, and for direct input in
SIMATIC software applications via OPC (optional via SIMATIC PC DiagMonitor ≥ V 2.1):
– Runtime meter
– Hard disk status
– System status (heartbeat)
– Automatic logging of all messages by means of log file
– Options for central monitoring of networked SIMATIC PCs
• RAID1 for automatic data mirroring on two hard disks
3.5 3.5 Features
Basic data
Design Panel mounting device, box
Processor
• Celeron M 370
1.5 GHz, 400 MHz Front Side Bus (FSB),
1024 KB Second Level Cache or
• Pentium M 730 / 760
1.6 or 2 GHz, 533 MHz Front Side Bus (FSB),
2048 KB Second Level Cache
RAM
• 128 MB SDRAM (DDR2)
• Expandable up to 2 GB SDRAM (DDR2)
Slots for add-ons 1x PCI 265 mm long
1x PCI 175 mm long
Graphic
• Graphic memory 8 to 132 MB SDRAM (set in system
BIOS), some using dynamic sharing of system RAM
• VGA: 1600 x 1200 / 32-bit color depth / 85 Hz
• DVI-I: 1600 x 1200 / 32-bit color depth / 60 Hz
Power supply
• 120 V / 230 V AC, 360 VA; varying voltage
• 24 V, 265 VA DC
Both with bridging of transient loss of voltage according
to NAMUR: max. 20 ms at 0.85 nominal voltage
Drives and storage media
Hard disk drives
• ≥ 40 GB Serial ATA; 3.5" or
• 1x 3.5" 80 GB hard disk or
• 2x 2.5" 60 GB hard disk or RAID1 system
DVD drive
• DVD ROM or
• DVD ROM/CD RW
Flash drive Slot for Compact Flash Card

Table of Contents