Installation
5.2 Installation of the device with the vertical mounting kit
SIMATIC Box PC 627
5-2 Operating Instructions, Release 05/2006, A5E00362052-03
Instructions for ceiling or wall mounting
Mounting examples
Material Hole diameter Mounting
Concrete 8 mm diameter, 60 mm depth Dowel: 8 mm, 50 mm
screws 4 mm, 50 mm
Plasterboard
(min. 13 mm thick)
14 mm diameter Tilting dowel
diameter 4 mm
min. length 50 mm
Metal
(min. 2 mm thick)
5 mm diameter Metal screws
diameter 4 mm
min. length 15 mm
Warning
Ensure that the wall or ceiling is capable of carrying at least four times the total weight of the
device (including the brackets and expansion modules). The total weight is approx. 7 kg.
5.2 5.2 Installation of the device with the vertical mounting kit
With the available optional vertical mounting kit you have the possibility to implement a place
saving installation.