Technical specifications
Resistance thermometer/silicon temperature sensors
Pt 100
Ni 100
Standard
± 1 K
Pt 100
Ni 100
Klima
± 0.8 K
Ni 1000
LG-Ni 1000
Standard
± 0.8 K
Ni 1000
LG-Ni
1000 Klima
± 0.8 K
KTY83/110
KTY84/130
± 2 K
± 2.7 K
Temperature error (relative to input range) ± 0.006 %/K / 0.006 K/K
Linearity error (relative to input range) ± 0.1 % / 0.1 K
Repeat accuracy (in transient state at 25 °C, relative to input
range)
± 0.1 % / ± 0.1 K
Status, interrupts, diagnostics
Interrupts none
Diagnostic functions none
Sensor selection data
Input ranges (rated values) / input impedance
Voltage
± 50 mV
± 500 mV
± 1 V
± 5 V
± 10 V
1 V to 5 V
0 V to 10 V
100 kΩ
Current
± 20 mA
0 mA to 20 mA
4 mA to 20 mA
100 Ω
Resistor/PTC
0 kΩ to 6 kΩ
0 Ω to 600 Ω
PTC
100 MΩ
ET 200PA SMART I/O modules
10.4 Analog input modules
ET 200PA SMART
Operating Instructions, 06/2019, A5E34192013-AB 159

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC ET 200PA SMART and is the answer not in the manual?

Siemens SIMATIC ET 200PA SMART Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC ET 200PA SMART
CategoryControl Systems
LanguageEnglish

Related product manuals