Commissioning the device
4.3 Parameterizing the Comfort Panel
Comfort Panels
144 Operating Instructions, 08/2018, A5E36770603-AC
– Alarms of type "Warning" with options:
Overwrite Select project data
The following lines contain options for overwriting
Recipes
Overwrite recipes of the HMI device with the
recipes of the project (optional).
User administration
data
Overwrite the user administration on the HMI
device with the user administration of the project
Upgrade Runtime upgrade
Runtime version on the HMI device is older than
the Runtime version of the project, versions are
compatible, upgrade of Runtime version on the
Upgrade Firmware upgrade
Firmware version on the HMI device is older than
the firmware version of the project, versions are
compatible, upgrade of firmware on the HMI
Downgrade Runtime downgrade
Runtime version on the HMI device is newer than
the Runtime version of the project, versions are
compatible, downgrade of Runtime version on the
Downgrade Firmware downgrade
Firmware version on the HMI device is newer
than the firmware version of the project, versions
are compatible, downgrade of firmware on the
– Alarms of type "Error" with option:
Upgrade Runtime upgrade
Runtime version on the HMI device is older than
the Runtime version of the project, versions are
incompatible, upgrade of Runtime version on the
Upgrade Firmware upgrade
Firmware version on the HMI device is older than
the firmware version of the project, versions are
incompatible, upgrade of firmware on the HMI
Downgrade Runtime downgrade
Runtime version on the HMI device is newer than
the Runtime version of the project, versions are
incompatible, downgrade of Runtime version on
the HMI device is required.
Downgrade Firmware downgrade
Firmware version on the HMI device is newer
than the firmware version of the project, versions
are incompatible, downgrade of firmware on the
Download Runtime download There is no Runtime software on the HMI device,
e.g. after update of the operating system.
Runtime software must be downloaded.