S5-115F Manual List of Operations
3
for organization blocks (OB)
for program blocks (PB)
for function blocks (FB)
for sequence blocks (SB)
Function
Execution time
in µsec.
CPU
942F
Load Operations (cont.)
N 1.6
I Q F T C
N
1.6
1330 *
N
21
N
N
N
N
N
N N
N
Ope-
ra-
tion
(STL)
L
L
L
L
L
1 RLO-depend.?
2 RLO affected ?
3 RLO reloaded?
Operands
L N 1.6
N
L
L
N N
N N
IW
Load an input word from the PII into accumulator 1: byte n
ACCUM 1(bits 8 to 15); byte n+1 ACCUM 1(bits 0 to 7)
Load an output word from the PIQ into accumulator 1: byte n
ACCUM 1 (bits 8 to 15); byte n+1 ACCUM 1 (bits 0 to 7)
Load an input byte of the digital/analog inputs from the
interrupt/timer PII into accumulator 1
QW
PY
PW N N 1330 *
Load an input byte of the digital/analog inputs from the
interrupt/timer PIQ into accumulator 1. Byte n ACCUM 1
(bits 8 to 15); byte n+1 ACCUM 1 (bits 0 to 7)
N
Load a flag byte into accumulator 11.6NNNFB
FW
Load a flag word into accumulator 1:byte n ACCUM 1 (bits 8
to 15); byte n+1 ACCUM 1 (bits 0 to 7)
L DL N N N 69
Load a data word (left-hand byte) of the current data block into
accumulator 1
L DR N N 71
L DW N N N 72
Load a data word of the current data block into ACCUM 1: byte
n ACCUM 1 (bits 8 to 15); byte n+1 ACCUM 1 (bits 0 to 7)
L
L
KB N N N 51 Load a constant (1-byte number) into accumulator 1
KC N N N 1.6
KF N 1.6 Load a constant (fixed-point number) into accumulator 1
NKH 1.6 Load a constant (hexadecimal code) into accumulator 1
Load a constant (bit pattern) into accumulator 1L KM N N N 1.6
L KY N N N 1.6 Load a constant (2-byte number) into accumulator 1
Load a constant (2 characters in ASCII format) into
accumulator 1
Load a data word (right-hand byte) of the current data block
into accumulator 1
* In the case of accesses to the 434 interrupt DI module, the time can increase by values up to the short discrepancy time ( 1.1.1).
EWA 4NEB 811 6149-02
A-5

Table of Contents

Other manuals for Siemens SIMATIC S5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC S5 and is the answer not in the manual?

Siemens SIMATIC S5 Specifications

General IconGeneral
Product type designationSIMATIC S5
Programming languageSTEP 5
Digital inputsVaries by model
Digital outputsVaries by model
Analog inputsVaries by model
Analog outputsVaries by model
Supply voltage24V DC
CPU TypeVaries by model
MemoryVaries by model
Digital I/OVaries by model
Analog I/OVaries by model
CommunicationPROFIBUS
Operating Temperature0°C to 60°C
Relative Humidity5% to 95% (non-condensing)

Related product manuals