Installing and connecting the device
3.2 Installing the built-in device
IFP V2, IFP V2 PRO, IFP V2 ETH
42 Operating Instructions, 03/2023, A5E46641410-AE
Procedure
For attachment on DIN rail or on the wall, fasten the
mounting rail in one of the lateral or rear guides in the
enclosure of the Transceiver
Unit according to the de-
The adjacent example shows the lateral mounting of
the mounting ra
il. The mounting rail is attached to the
Unit in the same way.
Push the mounting rail into the guide from below
until it stops.
Fasten the mounting rail using the supplied cross-tip
cylinder head screw, torque 0.8 Nm
3.2 Installing the built-in device
3.2.1 Notes on installation
Before installing the device, ensure that the installation location complies with the following:
Use according to IEC/UL 61010-2-201 requires an appropriate enclosure
The rear of the built-in device is classified as "Open Equipment" according to
IEC/UL 61010-2-201 for use in industrial control equipment.
For approval and operation according to IEC/UL 61010-2-201, the device must be installed
in an enclosure or integrated in a cabinet. The enclosure or the cabinet must provide
protection against electric shock and the spread of fire. The enclosure or the cabinet must
meet the requirements for mechanical strength and the degree of protection for the
• Position the device so that it is not exposed to direct sunlight.
• Position the device so that it is easily accessible for the operator.
• Choose a suitable installation height.
• Ensure that the air vents of the device are not covered as a result of installation. Observe
the permitted mounting positions.