Technical Data
4.2 Technical data for D445
D4x5
Manual, 03/2007 Edition
51
Connection values
Table 4-6 Electrical connection values
Parameters Value range
Supply voltage 24 VDC (permissible range: 20.4 to 28.8 V)
Current consumption from 24 V Typical current consumption: 2 A
(with no load at inputs/outputs, no supply from DRIVE-
CLiQ I/O or PROFIBUS)
Power loss 48 W
Starting current 6 A
Dimensions and weight
Table 4-7 Dimensions and weight of a D445
Parameters Values
Dimensions W x H x D [mm]
• Without mounting and fan/battery module
• With mounting and fan/battery module
(max. expansion)
• 50x420x272
• 50x420x272
Weight of SIMOTION D445 [g] Approximately 3600
Weight of SIMOTION CF card [g] 7
Ambient conditions
Table 4-8 Environmental requirements
Parameters Values
Permissible ambient temperature
• Storage and transport
• Operation
• -40° C to +70° C
• 0 °C to +55 °C up to 2000 m above sea level
Starting at an altitude of 2000 m, the maximum
ambient temperature decreases by 7 °C every 1000 m
Permissible relative humidity
(without condensation)
5% to 95%
Installation altitude Up to 5000 m above sea level
Organic/biological influences
• Storage
• Transport
• Operation
• Class 1B1 according to EN 60 721-3-1
• Class 2B1 according to EN 60 721-3-2
• Class 3B1 according to EN 60 721-3-3
Pollution degree 2 according to EN 60 664-1
Degree of protection according to IEC 529 IP20