EasyManua.ls Logo

Siemens SIMOTION D45 Series - Table 4-6 Electrical Connection Values; Table 4-7 Dimensions and Weight of a D445; Table 4-8 Environmental Requirements

Siemens SIMOTION D45 Series
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Data
4.2 Technical data for D445
D4x5
Manual, 03/2007 Edition
51
Connection values
Table 4-6 Electrical connection values
Parameters Value range
Supply voltage 24 VDC (permissible range: 20.4 to 28.8 V)
Current consumption from 24 V Typical current consumption: 2 A
(with no load at inputs/outputs, no supply from DRIVE-
CLiQ I/O or PROFIBUS)
Power loss 48 W
Starting current 6 A
Dimensions and weight
Table 4-7 Dimensions and weight of a D445
Parameters Values
Dimensions W x H x D [mm]
Without mounting and fan/battery module
With mounting and fan/battery module
(max. expansion)
50x420x272
50x420x272
Weight of SIMOTION D445 [g] Approximately 3600
Weight of SIMOTION CF card [g] 7
Ambient conditions
Table 4-8 Environmental requirements
Parameters Values
Permissible ambient temperature
Storage and transport
Operation
-40° C to +70° C
0 °C to +55 °C up to 2000 m above sea level
Starting at an altitude of 2000 m, the maximum
ambient temperature decreases by 7 °C every 1000 m
Permissible relative humidity
(without condensation)
5% to 95%
Installation altitude Up to 5000 m above sea level
Organic/biological influences
Storage
Transport
Operation
Class 1B1 according to EN 60 721-3-1
Class 2B1 according to EN 60 721-3-2
Class 3B1 according to EN 60 721-3-3
Pollution degree 2 according to EN 60 664-1
Degree of protection according to IEC 529 IP20

Table of Contents

Related product manuals